  1. Parts 1 and Part 2 of SS 563 replace SS CP 19: 2000 and its amendments. SS 563 : Part 1 is a modified adoption of the first edition of ISO 30061:2007 – ‘Emergency lighting’. It is not identical to the ISO Standard because it includes the national fire code requirements for emergency evacuation.

  2. ss 563-2:2010 (2017) Code of practice for the design, installation and maintenance of emergency lighting and power supply systems in buildings - Part 2 : Installation requirements and maintenance procedures

  3. SINGAPORE STANDARD. Code of practice for the design, installation and maintenance of emergency lighting and power supply systems in buildings. – Part 2 : Installation requirements and maintenance procedures. Incorporating Amendment No. 1 and No. 2 Confirmed 2017. Published by. SS 563-2:2010(2017)+A2:2017. (ICS 91.140.50; 91.160.10)

  4. www.scdf.gov.sg › docs › default-sourceCHAPTER 8

    SS.563 requires that horizontal illuminance in the centre line of any escape route shall not be less than 0.5 lux, measured at the floor, for minimum duration of 1 hour. The positioning of lighting shall be so arranged that the failure of any single lighting unit, such as the burning out of a bulb, will not leave any area in darkness.

  5. The use of self-luminous exit and directional signs powered by radioactive material are permitted in buildings, provided the signs comply with UL 924, SS 563 and SS 508 (Part 1, 2, 3 & 5). Either graphic or text format can be used for the design of the signage.

  6. www.scdf.gov.sg › firecode2023 › firecode2023Codes & Standards | SCDF

    Mar 1, 2024 · ss en 3-8 Portable Fire Extinguishers - Part 8 : Additional requirements to SS EN 3-7 for the construction, resistance to pressure and mechanical tests for extinguishers with a maximum allowable pressure equal to or lower than 30 bar

  7. The SS 563 Parts 1 and 2: 2010 - Design, Installation and Maintenance of Emergency Lighting and Power Supply Systems in Buildings was officially launched on 24 March 2011 to replace CP19:2000.

  8. Nov 20, 2019 · SS 563-2: 2010 (2017) Code of Practice for the design, installation and maintenance of Emergency Lighting and Power Supply Systems in buildings - Part 2: Installation requirements and maintenance procedure. Who is responsible for the Emergency Lighting System? Building Owners and Council Members are responsible by regulation.

  9. SS 563-1-2010(2017)+A1-2017_Preview.pdf - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Scribd is the world's largest social reading and publishing site.

  10. Nov 12, 2019 · However, this simple sign system becomes extremely vital during emergencies, indicating the escape routes to evacuees and, thus, saving lives. During an evacuation, visibility may be low and the situation chaotic, so being able to locate an exit could mean the difference between life and death.